seebest

Product Center

Building amplifier

Product Parameter

  • Basic parameter
  • frequency range(MHz):45~750
  • Nominal gain(dB):30
  • flatness in band :±0.75
  • test port:-10
  • nominal output level(dBμV):72
  • nominal output leve(dBμV):102
  • gain adjustment range(dB):0~20
  • slope adjustment range(dB):0~18
  • composite triple beat(dB):≥64
  • Composite Second beat ratio(dB):≥62
  • signal communication acoustic ratio(dB):>66
  • noise factor(dB):≤8
  • reflection loss(dB):≥16
  • lightning resistance(KV):5(10/700μS)
  • supply voltage:AC40V~60V  AC220V±10%/50Hz
  • consumed power(W):15
  • External dimension(mm):270×195×85mm
  • Applicable range:applicable to the amplification of CATV system branch or distribution power

Product Parameter

  • Basic parameter
  • frequency range(MHz):45~750
  • Nominal gain(dB):30
  • flatness in band :±0.75
  • test port:-10
  • nominal output level(dBμV):72
  • nominal output leve(dBμV):102
  • gain adjustment range(dB):0~20
  • slope adjustment range(dB):0~18
  • composite triple beat(dB):≥57
  • Composite Second beat ratio(dB):≥56
  • signal communication acoustic ratio(dB):>66
  • noise factor(dB):≤8
  • reflection loss(dB):≥16
  • lightning resistance(KV):5(10/700μS)
  • supply voltage:AC40V~60V  AC220V±10%/50Hz
  • consumed power(W):10
  • External dimension(mm):270×195×85
  • Applicable range:applicable to the amplification of CATV system branch or distribution power

Product Parameter

  • Basic parameter
  • frequency range(MHz):45~750
  • Nominal gain(dB):30
  • flatness in band :±0.75
  • test port:-10
  • nominal output level(dBμV):118
  • nominal output leve(dBμV):70
  • gain adjustment range(dB):0~20
  • slope adjustment range(dB):0~18
  • composite triple beat(dB):≥54
  • noise factor(dB):≤7
  • reflection loss(dB):≥12
  • lightning resistance(KV):5(10/700μS)
  • supply voltage:AC220V±10%
  • consumed power(W):10
  • External dimension(mm):223×180×85
  • Applicable range:applicable to the amplification of CATV system branch or distribution power

Product Parameter

  • Basic parameter
  • frequency range(MHz):45~750
  • Nominal gain(dB):30
  • flatness in band :±0.75
  • test port:-10
  • nominal output level(dBμV):117
  • nominal output leve(dBμV):70
  • gain adjustment range(dB):0~20
  • slope adjustment range(dB):0~18
  • composite triple beat(dB):≥54
  • noise factor(dB):≤7
  • reflection loss(dB):≥12
  • lightning resistance(KV):5(10/700μS)
  • supply voltage:AC220V±10%
  • consumed power(W):6
  • External dimension(mm):223×180×85
  • Applicable range:applicable to the amplification of CATV system branch or distribution power

Product Parameter

  • Basic parameter
  • frequency range(MHz):45~750
  • Nominal gain(dB):30
  • flatness in band :±0.75
  • test port:-10
  • nominal output level(dBμV):117
  • nominal output leve(dBμV):70
  • gain adjustment range(dB):0~20
  • slope adjustment range(dB):0~18
  • composite triple beat(dB):≥54
  • noise factor(dB):≤7
  • reflection loss(dB):≥12
  • lightning resistance(KV):5(10/700μS)
  • supply voltage:AC220V±10%
  • consumed power(W):6
  • External dimension(mm):223×180×85
  • Applicable range:applicable to the amplification of CATV system branch or distribution power

Product Parameter

  • Basic parameter
  • frequency range(MHz):45~750
  • Nominal gain(dB):30
  • flatness in band :±0.75
  • test port:-10
  • nominal output level(dBμV):117
  • nominal output leve(dBμV):70
  • gain adjustment range(dB):0~20
  • slope adjustment range(dB):0~18
  • composite triple beat(dB):≥52
  • noise factor(dB):≤7
  • reflection loss(dB):≥12
  • lightning resistance(KV):5(10/700μS)
  • supply voltage:AC220V±10%
  • consumed power(W):5
  • External dimension(mm):170×135×60
  • Applicable range:applicable to the amplification of CATV system branch or distribution power

Product Parameter

  • Basic parameter
  • frequency range(MHz):45~750MHZ
  • Nominal gain(dB):30
  • flatness in band :±0.75
  • test port:non
  • nominal output level(dBμV):72
  • nominal output leve(dBμV):102
  • gain adjustment range(dB):0~20
  • slope adjustment range(dB):0~18
  • composite triple beat(dB):≥64
  • Composite Second beat ratio(dB):≥62
  • signal communication acoustic ratio(dB):>66
  • noise factor(dB):≤6
  • reflection loss(dB):≥16
  • lightning resistance(KV):5(10/700μS)
  • supply voltage:AC40V~60V  AC220V±10%/50Hz
  • consumed power(W):15
  • External dimension(mm):270×195×85mm
  • Applicable range:applicable to the amplification of CATV system branch or distribution power

Product Parameter

  • Basic parameter
  • frequency range(MHz):45~860
  • Nominal gain(dB):30
  • flatness in band :±0.75
  • test port:non
  • nominal output level(dBμV):72
  • nominal output leve(dBμV):102
  • gain adjustment range(dB):0~20
  • slope adjustment range(dB):0~18
  • composite triple beat(dB):≥64
  • Composite Second beat ratio(dB):≥62
  • signal communication acoustic ratio(dB):>66
  • noise factor(dB):≤6
  • reflection loss(dB):≥16
  • lightning resistance(KV):5(10/700μS)
  • supply voltage:A: ~220±10%        B:~40-60V
  • consumed power(W):15
  • External dimension(mm):270×195×85mm
  • Applicable range:applicable to the amplification of CATV system branch or distribution power

Product Parameter

  • Basic parameter
  • frequency range(MHz):45~750
  • Nominal gain(dB):30
  • flatness in band :±0.75
  • test port:illustration branch 110/distribution
  • nominal output level(dBμV):72
  • nominal output leve(dBμV):102
  • gain adjustment range(dB):0~20
  • slope adjustment range(dB):0~18
  • composite triple beat(dB):≥64
  • Composite Second beat ratio(dB):≥62
  • signal communication acoustic ratio(dB):>66
  • noise factor(dB):≤8
  • reflection loss(dB):≥16
  • lightning resistance(KV):5(10/700μS)
  • supply voltage:AC40V~60V  AC220V±10%/50Hz
  • consumed power(W):15
  • External dimension(mm):270×195×85mm
  • Applicable range:applicable to the amplification of CATV system branch or distribution power

Product Parameter

  • Basic parameter
  • frequency range(MHz):45~750
  • Nominal gain(dB):30
  • flatness in band :±0.75
  • test port:illustration branch 110/distribution
  • nominal output level(dBμV):72
  • nominal output leve(dBμV):102
  • gain adjustment range(dB):0~20
  • slope adjustment range(dB):0~18
  • composite triple beat(dB):≥57
  • Composite Second beat ratio(dB):≥56
  • signal communication acoustic ratio(dB):>66
  • noise factor(dB):≤8
  • reflection loss(dB):≥16
  • lightning resistance(KV):5(10/700μS)
  • supply voltage:AC40V~60V  AC220V±10%/50Hz
  • consumed power(W):10
  • External dimension(mm):270×195×85
  • Applicable range:applicable to the amplification of CATV system branch or distribution power

Product Parameter

  • Basic parameter
  • frequency range(MHz):45~860
  • Nominal gain(dB):30
  • flatness in band :±0.75
  • test port:illustration branch 110/distribution204
  • nominal output level(dBμV):72
  • nominal output leve(dBμV):102
  • gain adjustment range(dB):0~20
  • slope adjustment range(dB):0~18
  • composite triple beat(dB):≥55
  • Composite Second beat ratio(dB):≥54
  • signal communication acoustic ratio(dB):>66
  • noise factor(dB):≤8
  • reflection loss(dB):≥16
  • lightning resistance(KV):5(10/700μS)
  • supply voltage:AC40V~60V  AC220V±10%/50Hz
  • consumed power(W):10
  • External dimension(mm):270×195×85
  • Applicable range:applicable to the amplification of CATV system branch or distribution power

Language: 中文 / ENGLISH